Activating Intellisync
When activated, intellisync applies to all 2D viewports of the chosen series. It can also be activated for all series at once.- Command bar: search for
Intellisync
- Keyboard (selected viewport):
Command + a
(Mac) orControl + a
(Windows) - Keyboard (All series):
Shift + Command + a
(Mac) orShift + Control + a
(Windows) - Mouse: Through the action dropdown in the top right of the given viewport
Intellisync with orthogonal imaging axis
Intellisync with label mirroring and weighted MRIs
Troubleshooting and limitations
- Reference lines are computed based on image position patient and image orientation patient headers in each DICOM instance. Therefore, reference lines are only available for data sourced from DICOM files.
- For scroll syncing, the absolute world position is used. This means that data must be registered correctly. This feature will work best on data with identical headers (position, direction, dimensions, and orientation).
- For scroll syncing, eligibility for syncing is computed based on the viewing angle of the viewports. Therefore, two views that seem like they should sync because they both say “AXIAL” may not if their coordinate systems don’t align well.